Reliable 3 MVA Power for High-Density Sites
This 3000 kVA Pad Mounted Transformer delivers stable 3 MVA capacity for data centers, industrial plants, and solar step-up applications in a compact ground-level footprint. The liquid-filled design (mineral oil or FR3 fluid) handles sustained full-load heat without the space and cost of a fenced substation yard.
- Rated Power: 3000 kVA (3 MVA)
- Weight: Approx. 8,500 kg – 10,500 kg
- Cooling: KNAN standard, KNAF optional (+15-25% temporary overload capacity)
- Insulating Fluid: Mineral Oil or FR3 (Vegetable Oil)
Foundation & Installation Requirements: The Transformer Mounting Pad
Installing a 3000 kVA Pad Mounted Transformer requires a properly engineered transformer mounting pad. Key requirements:
- Load Distribution: The transformer mounting pad must support both static weight and dynamic energization loads. Uneven leveling risks tank warping and gasket leaks over time.
- Cable Alignment: Low-voltage output uses heavy copper busbars - the window opening in the transformer mounting pad must align precisely with the transformer throat to avoid stress on cable terminations.
- Seismic Anchoring: External cleats bolt directly into the transformer mounting pad for units installed in seismic zones.
Detachable panel radiators on transformer side for natural
convection cooling.
Cooling Configuration (KNAN/KNAF)
Unlike smaller units, a 3000 kVA transformer generates significant core and winding heat.
- Corrugated vs. Radiators: While smaller units use corrugated walls, this model is typically equipped with detachable panel radiators to maximize surface area for natural convection (KNAN).
- Overload Capability: The tank design allows for the optional installation of cooling fans (KNAF), providing a temporary capacity boost (up to 15-25%) during peak demand spikes without overheating.
Dead-Front Safety Construction
Despite its high power rating, this unit maintains the safety standards of the pad-mount family.
- Tamper-Proof: The cabinet is secured with penta-head bolts and padlock recesses, ensuring no unauthorized access to live parts.
- Compartmentalization: High and low voltage compartments are separated by a rigid metal barrier, protecting operators during routine maintenance tasks like oil sampling or gauge reading.
Technical Data Sheet
|
Technical Parameter |
Data / Configuration |
|
Rated Power |
3000 kVA (3 MVA) |
|
Cooling Class |
KNAN (Natural) / KNAF (Forced Air Optional) |
|
Insulating Fluid |
Mineral Oil / FR3 (Vegetable Oil) |
|
Primary Voltage |
13.8kV / 24.94kV / 34.5kV (Loop Feed) |
|
Secondary Voltage |
480V / 600V / 4160V |
|
Tank Construction |
Sealed Tank with Welded Cover or Bolted Handholes |
|
Total Weight |
Approx. 8,500 kg - 10,500 kg |
|
Installation Base |
Concrete transformer mounting pad (Reinforced) |
Typical Application Context
- Crypto Mining & Data Centers: This 3000 kVA Pad Mounted Transformer provides high-density power feed (4000A+) to server containers, mounted on a reinforced transformer mounting pad for outdoor, space-efficient installation.
- Solar Step-Up: Aggregates power from multiple string inverters, stepping up voltage (e.g., 600V to 34.5kV) for grid transmission.
- Industrial Manufacturing: Powers heavy motor loads and pumps where indoor substation space is unavailable.
3000 kVA pad mounted step-up transformer installed at a
utility-scale solar farm.
FAQ
Q1: Can the primary/secondary voltage be customized for our local grid standards?
Yes. This 3000 kVA Pad Mounted Transformer supports primary voltages from 10-35kV and various secondary voltage options (480V/600V/4160V) to match your regional grid requirements. Please provide your voltage specification when inquiring.
Q2: What certifications does this transformer meet?
Standard units are built to IEEE/ANSI and IEC standards, with optional certifications (UL, CE) available depending on your destination market. Please confirm your required certification when placing an order.
Q3: Do you provide the transformer mounting pad, or do we need to build it ourselves?
The transformer mounting pad is typically constructed on-site by the customer's civil contractor, following our provided foundation drawings (load-bearing specs, cable window dimensions, anchor bolt layout). We can supply these drawings after order confirmation.
Q4: What is the lead time for a 3000 kVA unit?
Lead time typically ranges from 45-60 days depending on customization requirements (voltage configuration, cooling class, certifications). Exact timelines will be confirmed after technical specs are finalized.
Q5: What maintenance is required after installation?
Routine maintenance includes periodic oil sampling, gauge/level checks, and radiator inspection. With proper mounting pad installation and standard care, service life typically exceeds 25-30 years.
Hot Tags: 3000 kva pad mount three-phase oil-immersed distribution transformer, China 3000 kva pad mount three-phase oil-immersed distribution transformer manufacturers, suppliers, factory, 2500 KVA Pad Mount Three-Phase Oil-Immersed Distribution Transformer, 167 kva pad mount transformer, 5000 KVA Pad Mount Three-Phase Oil-Immersed Distribution Transformer, Single Phase Pad Mounted Transformer (URD Series), 1000 KVA Pad Mount Three-Phase Oil-Immersed Distribution Transformer, 25 kva pad mount transformer