6000 Kva Dry Type Transformer• Coil Material: Copper/Aluminumread more
• Primary Voltage: 10-35kv
• Working Efficiency: 50HZ/60HZ
• Cast resin dry type transformer
• Indoor dry type transformer
• Low... -
3750 Kva Dry Type Transformer• Coil Material: Copper/Aluminumread more
• Primary Voltage: 10-35kv
• Working Efficiency: 50HZ/60HZ
• Cast resin dry type transformer
• Indoor dry type transformer
• Low... -
1000 Kva Dry Type Transformer• Coil Material: Copper/Aluminumread more
• Primary Voltage: 10-35kv
• Working Efficiency: 50HZ/60HZ
• Cast resin dry type transformer
• Indoor dry type transformer
• Low... -
800 Kva Dry Type Transformer• Rated Capacity: 800 kVAread more
• Rated Primary Voltage: 11 kV
• Cooling: AN, air-natural
• Temperature Rise: 100K
• Enclosure: IP23
• Engineering Support: Custom Configuration... -
500 Kva Dry Type Transformer• Coil Material: Copper/Aluminumread more
• Primary Voltage: 10-35kv
• Working Efficiency: 50HZ/60HZ
• Cast resin dry type transformer
• Indoor dry type transformer
• Low... -
315 Kva Dry Type Transformer• Coil Material: Copper/Aluminumread more
• Primary Voltage: 10-35kv
• Working Efficiency: 50HZ/60HZ
• Cast resin dry type transformer
• Indoor dry type transformer
• Low... -
250 Kva Dry Type Transformer• Coil Material: Copper/Aluminumread more
• Primary Voltage: 10-35kv
• Working Efficiency: 50HZ/60HZ
• Cast resin dry type transformer
• Indoor dry type transformer
• Low... -
200 Kva Dry Type Transformer• Coil Material: Copper/Aluminumread more
• Primary Voltage: 10-35kv
• Working Efficiency: 50HZ/60HZ
• Cast resin dry type transformer
• Indoor dry type transformer
• Low...
General Purpose Isolation transformers are used to lower distribution voltages (480 or 600V) to lower voltages (typically 120/240 or 208Y120) for power distribution within commercial or...
dry-type transformers should be provided with a weather-resistant enclosure when used in outdoor applications. Facility management teams should also consider ambient temperature...
Dry type transformers insulated with Nomex® can be designed with a temperature rise up to 150K, requiring less conductor and core steel, which can result in a lower initial cost. The...
Dry Type Isolation Transformer. Dry Type Isolation. We make 3-Ø and 1-Ø Dry Type Isolation transformers up to 500kVA. Voltage rating we follow are normally 415/415, which the customer can specify any...
Transformers Rated 600 V and below Eaton’s single-phase and three-phase general purpose dry-type ventilated transformers are of the two-winding type, self-cooled, and are available in a...
Drive Isolation Transformer (DIT) is designed to specifically handle the mechanical stresses, voltage distortions, and harmonics associated with silicon-controlled rectifiers (SCR)...