Epoxy resin cast, oil-free power for data centers, metro systems and hospitals.

1600 kVA, three-phase, 50/60 Hz, IEC 60076-11
Primary up to 35 kV, secondary 0.4 / 0.433 kV (customizable)
No MOQ: a single customized unit is accepted
Lead time 4 weeks, as fast as 2 weeks
100% factory tested, FAT can be witnessed by live video
ISO 9001 · CE · CCC
Category
Dry Type Transformer
Share to
Send Inquiry
Description
Technical Parameters

1600 kVA Dry Type Transformer

 

product-6240-4160

A 1600 kVA dry type transformer is the point where a project's power budget gets decided: a single unit may feed a data hall, a station concourse or a hospital wing, so a wrong specification is expensive to correct. CHBEB (Beierbian Group Co., Ltd.) builds this epoxy resin cast transformer at its own production bases in Yueqing, Zhejiang and Nanjing, Jiangsu, with engineering led from the Beijing R&D center. It is made for EPC contractors, system integrators, distributors and end users who want an oil-free unit they can specify, verify and accept before it leaves the factory.

 

 

Where a 1600 kVA Rating Gets Specified

 

  • Data centers: continuous, dense load where a fire event or an unplanned outage is unacceptable.
  • Metro and rail: station and tunnel power distribution in enclosed underground spaces, where liquid-filled equipment is often restricted.
  • Hospitals: critical-care wings and building services where fire-safety rules and uptime both matter.
  • Industrial plants: production-line and utility feeders that need a low-maintenance transformer close to the load.

 

 

 

Three Risks in Large-Capacity Selection, and How We Close Them

 

 

  1. Grid mismatch. Voltage, frequency and vector group are fixed on the order before winding starts. Primary 10, 11, 20 or 35 kV; secondary 0.4 or 0.433 kV; 50 or 60 Hz; Dyn11 by default, other groups on request. Wider custom voltages run from 300 V to 35 kV.
  2. Thermal and site fit. Class F insulation is standard and Class H can be chosen. Air Natural (AN) cooling is standard, and Air Forced (AF) can be specified if your site expects irregular or growing load. Choose IP20 or IP23, and a stainless steel or aluminum alloy enclosure.
  3. Acceptance risk. Every unit goes through a Factory Acceptance Test (FAT) that your engineer can witness by live video, and the reports travel with the shipment.
product-6240-4160

 

 

 

Configuration Sheet: 1600 kVA Dry Type Transformer

 

 

Item Standard setting Options
Capacity 1600 kVA, three-phase Single-phase on request
Windings Copper Aluminum optional
Core Silicon steel Amorphous alloy optional
Installation Indoor, floor-mounted Skid-mounted optional
Standards IEC 60076-11, IEC 60726, GB/T 10228 ANSI/IEEE C57.12.01 and GOST-R on request
Losses, impedance, sound level, weight, dimensions Supplied with your quotation and drawings, matched to the chosen configuration -

 

 

 

Verification Before Shipment

 

Quality control is split into four checkpoints, each tied to a published standard:

  • Material intake: core steel loss and insulation heat rating are checked against GB/T 2521 and IEC 60641.
  • During production: lamination accuracy of ±0.02 mm and turn-to-turn voltage withstand are checked against JB/T 501 and IEEE C57.12.00.
  • Final test: no-load loss must stay within 102% of the rated value and partial discharge at or below 5 PC, following IEC 60076 and GB 1094.11.
  • Independent review: KEMA (Netherlands) and CQC can verify the results.
 

Grade A silicon steel from Baowu Steel and DuPont Nomex® / Vishay® insulation materials go into the build. On the test floor, the factory can apply up to 100 kV AC RMS withstand voltage and impulse levels up to 300 kV BIL, and the dry type insulation system has completed a 1,000-hour continuous run at 95°C. A team of 30+ inspectors, trained 200+ hours each year to CNAS requirements, runs these checks.

 

 

 

Confirm the Supplier, Not Just the Product

 

Large orders go through supplier audits, so we keep a Trust Pack ready: factory videos, key equipment lists, production and test flow, anonymized reference projects and management-system certificates. Remote video audits and third-party audit options such as SGS or TÜV can be arranged on request.

product-4032-2268

 

 

Ordering Terms for a 1600 kVA Dry Type Transformer

 

 

Quantity: no strict MOQ. A single customized unit is accepted, which suits phased data hall or station builds.

Lead time: standard 4 weeks, expedited as fast as 2 weeks. Lead time does not depend on product line, and the schedule can be coordinated with your project phases.

Payment: T/T with a 20% deposit. The balance is due once you approve the factory test report, before shipment.

Packing: export-grade packing and lashing, optional shock and tilt indicators, and moisture protection chosen to suit the route.

Trade terms and loading port: confirmed in the quotation.

Documents: drawings, test reports and certificates for your approval process.

 

 

Warranty and Support


 

1-year warranty on the complete unit and 1-year warranty on components, plus lifetime maintenance guidance. Our engineers handle spare parts, post-installation questions and field troubleshooting directly.

product-6240-4160

 

 

The Factory Behind It

 

CHBEB operates on more than 100 acres with 300+ production staff, 3 billion RMB in annual output value and 120+ patents (5 of them invention patents). It is trusted by State Grid, China Southern Power Grid and Sinopec, and works with 20+ distributors across 17+ countries. Certifications include ISO 9001, ISO 14001, ISO 45001, CE, CCC and GOST-R.

product-7728-5152
product-6240-4160
product-6240-4160
product-6240-4160

 

 

 

Questions Project Buyers Ask

 

Q: Can we order one unit for a first-phase build?

A: Yes. There is no strict minimum, so a single customized transformer is fine.

Q: How can our engineer sign off without traveling?

A: Join the FAT by live video, review the test report, and request a remote factory audit before paying the balance.

Q: How do we know it will fit our transformer room?

A: Dimensions, weight and sound level come with the quotation and drawings, so your designer can check clearance and ventilation before you commit.

Q: What if the load profile changes later?

A: Tell us the expected growth. AF cooling and Class H insulation can be specified at order stage, and the engineers will confirm the data for your configuration.

Q: What do we receive for the approval file?

A: Drawings, test reports and certificates, with the manufacturer's engineers available for queries.

Q: What are the payment steps?

A: 20% T/T deposit at order, balance after the factory test report is accepted and before the unit ships.

 

 

 

Get a Quote

Planning a 1600 kVA dry type transformer for a data center, metro line, hospital or plant? Send the primary and secondary voltage, frequency, room dimensions and delivery site. We will reply with a quotation, drawings and the loss, impedance, weight and sound data for your configuration.
Phone/WhatsApp: +86 18668091107 Email: chbebgroup@chbeb-ele.com

 

 

Hot Tags: 1600 kva dry type transformer, China 1600 kva dry type transformer manufacturers, suppliers, factory, 2500 kva dry type transformer, crt dry type transformer, dry type cast resin, dry type step down transformer, epoxy resin transformer, types of transformer

Powering the World with Premium Transformer Solutions

As a leading Chinese transformer manufacturer with decades of expertise, CHBEB proudly serves clients across 17 countries and counting. Our global footprint expands continuously as we:

  • Deliver customized power solutions for more than 10 international projects
  • Support over 20 trusted distributors worldwide
  • Manufacture reliable low-voltage transformers with 60+ years of technical excellence

Let's energize your next power project with Chinese precision and global reliability.

Get in Touch with CHBEB

Leave a message for more information about our products series, and request a quote or expert advice.