Product Overview
The 1250 kVA Dry Type Transformeris designed for reliable power distribution in manufacturing and processing facilities where dust, humidity, and industrial contaminants can challenge insulation performance. Its high-voltage windings are fully encapsulated in vacuum-cast epoxy resin with high Comparative Tracking Index (CTI) properties, helping resist surface tracking caused by conductive deposits and maintain dependable electrical insulation under demanding operating conditions.
Solid monolithic cast resin coil cylinder for 1250 kVA industrial
transformer.
Technical Specifications
|
Parameter |
Standard Specification |
|
Product Name |
1250 kVA Dry-Type Transformer |
|
Transformer Type |
Three-Phase Cast-Resin Dry-Type Distribution Transformer |
|
Rated Capacity |
1250 kVA |
|
Number of Phases |
Three-phase |
|
Rated Frequency |
50 Hz |
|
Rated Primary Voltage |
11 kV |
|
Rated Secondary Voltage |
0.415 kV |
|
HV Tapping Range |
±2 × 2.5%, 5 positions |
|
Tap-Changing Method |
De-energized tap changing |
|
Vector Group |
Dyn11 |
|
Short-Circuit Impedance |
6.0% |
|
No-Load Current |
≤1.1% |
|
Cooling Method |
AN, air-natural |
|
Insulation Construction |
Vacuum-cast epoxy-resin insulation with fully encapsulated HV windings |
|
Winding Material |
Copper |
|
Core Material |
Cold-rolled grain-oriented silicon steel |
|
Thermal Insulation Class |
Class F |
|
Winding Temperature Rise |
100 K |
|
Partial Discharge Level |
≤10 pC |
|
Environmental / Climatic / Fire Class |
E2, C2, F1 |
|
Enclosure Protection Degree |
IP23 |
|
Temperature Monitoring |
PT100 sensors, digital temperature controller, alarm and trip contacts |
|
Installation |
Indoor installation, continuous duty |
|
Service Conditions |
Maximum ambient temperature: 40°C; maximum altitude: 1,000 m |
|
Certification Standards |
Available according to IEC, IEEE/ANSI, UL, CSA, DOE (where applicable), CE/EN, UKCA, GOST/EAC, SASO/SABER, SONCAP, ISO, and other required certification schemes |
Advantages of CHBEB 1250 kVA Dry Type Transformer
CHBEB 1250 kVA dry type transformers combine cast-resin insulation, reinforced coil construction, and flexible cooling options for reliable industrial power distribution.
Monolithic Cast Coil Construction
Epoxy resin and fiberglass reinforcement form a solid coil structure that secures the winding conductors and helps resist deformation under electromechanical stress. This construction supports winding stability during short-circuit events.
Surface Insulation and Easy Maintenance
The smooth cast-resin surface helps resist surface tracking caused by dust and conductive contaminants. It also allows maintenance teams to remove accumulated dust more easily during routine inspections, reducing cleaning effort in industrial environments.
Forced-Air Cooling Capacity
Pre-installed fan mounting channels allow the transformer to be configured for forced-air (AF) cooling. Compared with natural-air cooling, forced airflow improves heat dissipation and may increase available capacity when supported by the rated design, helping accommodate load peaks and demanding motor-starting conditions.




Typical Application Context
- Automotive Manufacturing Plants
- Hyperscale Data Centers
- Tunnel Ventilation and Drainage Systems
- Heavy Industrial Processing Facilities
- Welding and Fabrication Workshops
- Chemical and Pharmaceutical Plants
- Mining and Mineral Processing Facilities
- Commercial and Industrial Buildings
Encapsulated 1250 kVA dry type transformer powering dusty
mining crushers.
Customize 1500 kVA Dry Type Transformer for Your Power Distribution Project
CHBEB provides configurable electrical, winding, cooling, protection, and documentation options to match project-specific power distribution requirements.
- Electrical Ratings - Customize primary and secondary voltage, frequency, impedance, vector group, and tap configuration according to project requirements.
- Winding & Core Materials - Select copper or aluminum windings and suitable core materials according to required electrical performance and operating conditions.
- Cooling Configuration - Configure natural air or forced-air cooling according to the required load capacity, installation conditions, and operating requirements.
- Insulation & Protection - Configure cast-resin insulation, temperature monitoring, enclosure protection, and other electrical protection requirements for the intended installation environment.
- Dimensions & Installation - Customize overall dimensions, terminal arrangements, enclosure configuration, and other structural details to suit available installation space and system connections.
- Testing & Documentation - Provide project-specific testing, technical drawings, nameplate information, and inspection documents according to customer or project requirements.

Quality Assurance & Testing by CHBEB for Transformer Manufacturing
CHBEB applies quality controls throughout material inspection, production, and final testing to maintain consistent performance and reliability for dry type transformers.
Incoming Material Inspection
Inspect silicon steel core materials, winding conductors, cast-resin insulation materials, and other key components before production. Material properties are verified against applicable GB/T and IEC requirements to ensure consistent input quality.
01
Production Process Control
Monitor core lamination, winding dimensions, insulation application, and cast-resin curing throughout manufacturing. Key process controls help maintain dimensional accuracy, insulation integrity, and consistent winding quality for dry type transformers.
02
In-Factory Quality Testing
Perform voltage ratio, winding resistance, load and no-load loss, impedance voltage, insulation resistance, withstand voltage, and partial discharge tests according to applicable IEC 60076 and GB 1094 standards. These tests verify the transformer's electrical performance and insulation condition before shipment.
03
Third-Party Testing
Support independent testing and certification through recognized organizations such as KEMA and CQC for applicable transformer projects, providing additional verification for project-specific quality and compliance requirements.
04
R&D Innovations in CHBEB Dry Type Transformer Manufacturing
CHBEB dry type transformers incorporate advanced R&D engineering to deliver maximum operational reliability and performance across demanding industrial environments.
Low-Loss Design
CHBEB optimizes magnetic circuit design and uses high-performance silicon steel sheets to improve the efficiency of dry type transformers. These technologies enable no-load losses to be reduced by 15–20% and load losses by 10–15%, helping lower energy consumption during long-term operation.
High Reliability Design
CHBEB develops reinforced winding, insulation, and structural designs to withstand demanding electrical and mechanical conditions. Its dry type transformers have passed short-circuit, overload, and vibration tests, with an annual product failure rate of less than 0.05%, supporting stable and reliable long-term operation.
High-Temperature Tolerance
CHBEB develops optimized winding and insulation systems for stable performance under elevated temperatures. Enhanced thermal design enables dry type transformers to maintain reliable operation at 95°C for 1,000 hours, supporting consistent electrical and insulation performance in high-temperature environments.
Material Innovation
CHBEB applies high-quality silicon steel sheets and advanced insulation materials to improve the electrical, thermal, and mechanical performance of dry type transformers. These material innovations can extend service life by 20–30% and increase efficiency by 5–8%, supporting more durable and energy-efficient operation.
Comprehensive Service Support from CHBEB for Your Transformer Projects
CHBEB provides practical support from technical evaluation and project coordination to delivery and after-sales service.
Technical Support & Free Design Drawings
CHBEB provides technical assistance and drawings to help customers confirm transformer specifications and equipment requirements before production.
Support includes:
• Free technical drawings for project evaluationa
• Transformer specification and selection support
• Electrical and installation requirement consultation
• Product dimension and interface confirmation
• Responsive technical communication
Fast Production & Logistics Support
CHBEB coordinates production and shipment according to project schedules, product requirements, and delivery conditions.
Support includes:
• Standard lead time of 3–6 weeks
• Expedited delivery available within 1 week
• Production scheduling based on project requirements
• Export packaging for transformer transportation
• Shipping and logistics coordination
After-Sales & Lifecycle Support
CHBEB provides technical assistance and warranty coverage to support reliable transformer operation throughout its service life.
After-sales support includes:
• 3-year warranty for complete transformers
• 2-year warranty for spare parts
• Free lifecycle maintenance guidance
• Installation and commissioning guidance
• Technical troubleshooting and operation support
FAQ
Q: Can a 1250 kVA dry type transformer operate in parallel with an existing unit?
A: Yes, provided the transformers have compatible voltage ratios, vector groups, impedance values, phase sequences, and tap settings. CHBEB recommends reviewing the existing unit's nameplate and test data before confirming parallel operation.
Q: How can buyers determine whether 1250 kVA is sufficient for their facility?
A: Evaluate peak demand, motor starting currents, nonlinear loads, and planned capacity expansion. Buyers should also consider ambient temperature and installation altitude, as these conditions can affect the transformer's available capacity. CHBEB can review the load profile to help confirm suitability.
Q: Is a 1250 kVA dry type transformer suitable for dusty industrial environments?
A: The cast-resin insulation helps protect the high-voltage windings against dust contamination and surface tracking. However, the overall suitability depends on the enclosure, ventilation arrangement, and type of contaminants present. CHBEB recommends confirming these conditions before selecting the final configuration.
Q: What should buyers consider when selecting transformer installation space?
A: Allow sufficient clearance for ventilation, cable connections, inspection, and maintenance. Buyers should also check floor loading, access routes for equipment handling, and local electrical code requirements before finalizing the installation layout.
Q: How should the transformer be coordinated with upstream protection equipment?
A: The upstream circuit breaker or fuse should be selected according to the transformer's rated voltage, full-load current, inrush characteristics, and available fault current. Protection settings must also coordinate with downstream devices. CHBEB recommends confirming these details with the project's electrical engineer.
Q: Can forced-air cooling increase the transformer's rated capacity?
A: Forced-air cooling can increase the available capacity of a transformer designed for both AN and AF operation. The permitted capacity depends on the manufacturer's ratings, temperature limits, and cooling configuration. Buyers should confirm the approved AF rating with CHBEB rather than assume a fixed overload percentage.
Hot Tags: 1250 kva dry type transformer, China 1250 kva dry type transformer manufacturers, suppliers, factory, 1000 Kva Dry Type Transformer, 225 kva dry type transformer, dry type power transformer, air insulated dry type, cast coil dry type transformer, air cooled transformer dry type