Key Advantages
Engineered for reliable medium-load distribution, this 100 kVA pad-mounted transformer offers copper or aluminum coil options and supports both 50 Hz and 60 Hz operation. Its compact footprint reduces site space requirements.
Product Use
ZBW-12/0.4 pre-installed substation is a type of American-style prefabricated box-type substation. As an integrated prefabricated product, it combines the cable of the distribution network power supply unit, high-voltage control and protection devices, substation components, and power distribution equipment. It is widely used in urban and rural power distribution networks.
The product is equipped with high-voltage load switches and high-voltage fuses in the transformer oil tank, and has two structural forms: integrated transformer tank and separate transformer tank. The tank adopts a fully sealed structure, and is equipped with oil temperature gauges, oil level gauges, pressure gauges, pressure release valves, drain valves, and other components to monitor the operation status of the transformer.
According to the power supply mode, the product is classified into ring network type and terminal type. To make this product more suitable for the actual requirements of China's power grid, our company has also launched plug-type fuses, which do not affect the performance of transformer oil.
Based on the complexity of low-voltage outgoing circuits, ZBW-12/0.4 products are divided into three cabinet types: standard type, enhanced type, and comprehensive type. This allows users and design units to make more flexible and cost-effective selections.
Model Description
- Taking the ZBW series as an example, the model is represented as ZBW - 12/0.4 - □ - □ - □.
- The first part "ZBW" indicates the prefabricated substation.
- "12/0.4" represents the rated voltage levels, with 12kV for the high - voltage side and 0.4kV for the low - voltage side.
- The subsequent boxes respectively denote the high - voltage measurement of rated voltage (KV), low - voltage measurement of rated voltage (KV), and rated capacity of the transformer (KVA).

Environmental Conditions of Use
1. Cooling condition: Air self-cooling
2. Operating environment:
The outdoor ambient temperature shall not be higher than 40℃ or lower than -45℃; the altitude shall not exceed 1000m; the monthly average temperature shall not exceed 30℃; the annual average temperature shall not exceed 20℃.
At 25℃, the relative humidity of the air shall not exceed 95%, and the monthly average relative humidity shall not exceed 90%.
Horizontal acceleration shall not exceed 0.3g; vertical acceleration shall not exceed 0.15g.
The installation environment shall be free from obvious pollution, as well as explosive or corrosive gases and dust. The installation site shall be free from violent vibration and impact, and the equipment shall be installed on a cement platform or other flat, solid platforms.
3. Note: If the intended use conditions deviate from the above technical specifications, the user shall negotiate with the company.
Product Advantages
1. Compact structure and small size: Its volume is only about 1/3 to 1/5 of that of domestic European-style box-type substations with the same capacity, greatly reducing the floor area.
2. Fully sealed and fully insulated structure: It requires no insulation distance and provides reliable personal safety protection.
3. Flexible high-voltage connection and power supply mode: The high-voltage connection can be used for both ring network and terminal connections, featuring flexible power supply mode and high reliability.
4. Excellent transformer performance: The transformer has excellent performance, with low loss, low noise, and low temperature rise. It also has strong overload capacity, as well as short-circuit and impact resistance.
5. Adaptable to low-voltage outgoing requirements: It can meet the requirements of various low-voltage outgoing circuits, and can be selected according to existing schemes or customized as required.
6. Two types of cable connections available: There are two options for cable connections: cable head plugs and 200A/600A elbow-type "T"-shaped fixed cable joints. A fully insulated zinc oxide arrester can be configured; the 200A cable head supports live plugging and serves as an isolating switch.
Product Characteristics
1. The product features small size, a compact structure, and easy installation.
2. It can be used for both ring network and terminal applications, and provides reliable personal safety protection.
3. The product has low loss, low noise, and superior performance.
4. The cabinet adopts an anti-theft structure.
5. It also has a low temperature rise and strong overload capacity.

Basic Construction and Technical Requirements
● Foundation Bearing Capacity and Protection
The foundation bearing capacity shall be not less than 100 kPa.
-If the foundation is located in highlands, external drainage systems shall be provided around it.
-The foundation shall be built with red brick cement mortar, and both inner and outer walls shall be plastered with 20mm-thick 1:2 cement mortar mixed with 3% waterproofing agent to enhance waterproofing.
-The concrete foundation surface shall be flat, and after installation of the prefabricated substation, the surrounding foundation shall be sealed with cement.
● Structure and Embedded Parts
-The bottom of the cable chamber shall be slightly inclined toward the water collection pipe to prevent water accumulation.
-A diamond-shaped expanded steel mesh (150×300 frame, 10×20 mesh size) shall be welded inside the louver frame, with reinforcement ribs embedded into the wall for enhanced strength.
-Grounding bars and cable fixing brackets shall be pre-embedded, and their shapes and positions shall be determined according to actual site conditions.
--The positions of incoming and outgoing cable holes shall also be determined as required on-site.
● Operation and Space
After installation of the prefabricated transformer substation, an operation clearance of not less than 1.5m shall be reserved in front of the switch to ensure safe operation and maintenance.
● Grounding System
- The grounding trunk shall be led out from the cable trench, and may be arranged around the ring main unit or extended to the grounding electrode from one side.
- The grounding grid shall be constructed with Φ12mm galvanized round steel or 30×4mm galvanized flat steel.
- The grounding resistance shall be ≤4Ω, in compliance with the requirements of the power authority.
● Construction Standards and Flexibility
-Foundation construction shall comply with JGJ/T16-92 "Code for Electrical Design of Civil Buildings".
-The dimensions shown in the drawings are recommended values. Cable wells can be arranged in three or four directions according to site conditions to meet different incoming line requirements.
Product Parameters
|
S/N |
Name |
Unit |
Technical Parameter |
|
1 |
Rated Voltage |
KV |
10/0.4 |
|
2 |
High-voltage Side Rated Voltage |
KV |
10 |
|
3 |
Low-voltage Side Rated Voltage |
KV |
0.4 |
|
4 |
Maximum operating voltage (High voltage side) |
KV |
12 |
|
5 |
Rated Frequency |
Hz |
50 |
|
6 |
Rated Capacity |
KVA |
150-1600 |
|
7 |
High-voltage Switch Heat Stable Capacity |
KA |
20/26 |
|
8 |
Low-voltage Main Circuit Breaker Rated Short-circuit Breaking Capacity |
KA |
35 |
|
9 |
Low-voltage Distribution Circuit Breaker Rated Short-circuit Breaking Capacity |
KA |
35 |
|
10 |
High-voltage Load Switch Transfer Current |
A |
>1500 |
|
11 |
1 min Power Frequency Withstand Voltage |
KV |
35 |
|
12 |
Lightning Impulse Voltage |
KV |
75 |
|
13 |
Cooling Mode |
- |
Oil immersed self-cooling |
|
14 |
High-voltage Backup Fuse Breaking Current |
KA |
50 |
|
15 |
Breaking Current of Plug-in Fuse |
KA |
2.5 |
|
16 |
Ambient Temperature |
℃ |
-35 ~ +40 |
|
17 |
Coil Allowable Temperature Rise |
K |
65 |
|
18 |
No-load Voltage Regulation |
% |
±5% or ±2 × 2.5% |
|
19 |
Noise Level |
dB |
<50 |
|
20 |
Protection Grade of Box Shell |
- |
Not less than IP3X |
Insulation Level
|
Rated voltage(KV) |
10 |
0.4 |
||
|
Transformer |
Switch to ground and phase to phase |
Between disconnectors |
||
|
Power frequency withstand voltage (KV) |
35 |
42 |
48 |
2.5 |
|
Peak value of impulse withstand voltage(KV) |
75 |
75 |
85 |
– |
Transformer
Selected new S9 series transformer body, low loss, good overload capacity, strong short-circuit resistance, all fasteners are protected. The S11 series ring jointless core transformer with better performance can also be selected.
|
Capacity KVA |
Voltage KV |
Join group label |
No-load current % |
No load loss W |
Impedance voltage % |
Load loss |
|||||
|
High tension |
Low pressure |
S9 |
S10 |
S11 |
S9 |
S10 |
S11 |
||||
|
160 |
10±5% or 2×2.5% |
0.4 |
Dyn11 Yno |
1.4 |
1.4 |
0.2 |
400 |
320 |
255 |
4.0 |
2200 |
|
200 |
1.3 |
1.3 |
0.2 |
480 |
380 |
305 |
2600 |
||||
|
250 |
1.2 |
1.2 |
0.2 |
560 |
450 |
360 |
3050 |
||||
|
315 |
1.1 |
1.1 |
0.2 |
670 |
530 |
425 |
3650 |
||||
|
400 |
1.0 |
1.0 |
0.15 |
800 |
650 |
505 |
4300 |
||||
|
500 |
1.0 |
1.0 |
0.15 |
960 |
750 |
605 |
5100 |
||||
|
630 |
0.9 |
0.9 |
0.15 |
1200 |
910 |
755 |
6200 |
||||
|
800 |
0.8 |
0.8 |
0.15 |
1400 |
1080 |
980 |
7500 |
||||
|
1000 |
0.7 |
0.7 |
- |
1700 |
1260 |
- |
4.5 |
10300 |
|||
|
1250 |
0.6 |
0.6 |
- |
1950 |
- |
- |
12000 |
||||
|
Item Name |
Units |
315A |
630A |
|
|
Rated voltage |
KV |
12 |
12 |
|
|
Maximum current |
A |
315 |
630 |
|
|
Rated frequency |
Hz |
50 |
50 |
|
|
Rated short-circuit closing current |
kA |
31.5 |
50 |
|
|
Rated short-time withstand current |
kA |
12.5 |
50 |
|
|
Rated short endurance time |
S |
2 |
2 |
|
|
Mechanical life |
Second-rate |
2000 |
2000 |
|
|
Lightning impulse test |
Phase to phase |
KV |
75 |
75 |
|
Isolation fracture |
85 |
85 |
||
|
1min power frequency withstand voltage |
Phase to phase |
KA |
42 |
42 |
|
Isolation fracture |
48 |
48 |
||
|
Rated peak withstand current |
KV |
31.5 |
50 |
|
|
Capacity |
A |
B |
C |
H |
Weight KG |
|
200kVA and below |
1830 |
1420 |
820 |
1850 |
< 2800 |
|
250-400kVA |
1830 |
1450 |
850 |
1980 |
3000-3300 |
|
500-630kVA |
1830 |
1480 |
880 |
2070 |
3600-3950 |
|
800kVA |
2200 |
1700 |
950 |
2170 |
4500 |
Note:The above is the standard size for reference.
|
Capacity |
A |
B |
C |
H |
Weight KG |
|
315kVA |
2560 |
1600 |
600 |
1000 |
3050 |
|
400kVA |
2560 |
1600 |
600 |
1000 |
3270 |
|
500kVA |
2560 |
1600 |
600 |
1000 |
3400 |
|
630kVA |
2560 |
1600 |
600 |
1000 |
3900 |
|
800kVA |
2760 |
1600 |
800 |
1000 |
4200 |
|
1000kVA |
2760 |
1950 |
800 |
1000 |
4800 |
|
1250kVA |
2910 |
1950 |
800 |
1000 |
5400 |
|
1600kVA |
2200 |
1700 |
950 |
2170 |
4500 |
Note:The above is the standard size for reference.
Drawings



Detailed Views






Packing and Shipping



Customer Factory Inspection






Hot Tags: 100 kva pad mount three-phase oil-immersed distribution transformer, China 100 kva pad mount three-phase oil-immersed distribution transformer manufacturers, suppliers, factory, 2500 KVA Pad Mount Three-Phase Oil-Immersed Distribution Transformer, 167 kva pad mount transformer, 5000 KVA Pad Mount Three-Phase Oil-Immersed Distribution Transformer, Single Phase Pad Mounted Transformer (URD Series), 1000 KVA Pad Mount Three-Phase Oil-Immersed Distribution Transformer, 25 kva pad mount transformer