50 KVA Pad Mount Three-Phase Oil-Immersed Distribution Transformer

50 KVA Pad Mount Three-Phase Oil-Immersed Distribution Transformer

Details
• Coil Material: Copper/Aluminum
• Primary Voltage: 10-35kv
• Working Efficiency: 50HZ/60HZ
• Pad mounted distribution transformers
• Single-phase /three-phase
Category
Pad Mounted Transformer
Share to
Send Inquiry
Description
Technical Parameters

Key Advantages

 

Featuring compact design and reliable performance, this 50 kVA pad-mounted transformer uses copper or aluminum windings and supports primary voltages of 10–35 kV at 50/60 Hz, providing efficient operation for residential or small-scale urban distribution networks.

 

 

 

Product Use

 

The pad - mounted transformer serves as an integrated prefabricated product that combines distribution network power supply unit cables, high - voltage control, protection, substation, and power distribution equipment. It is widely applied in urban and rural distribution networks. The transformer and high - low voltage equipment are closely connected into one unit. Three sides of the transformer are exposed to the air, ensuring good heat dissipation conditions. Moreover, the transformer can be separated from the high - low voltage equipment housing, facilitating maintenance. Power distribution switchgear is installed on the high and low voltage sides.

 

 

 

Model Description

 

  • Taking the ZBW series as an example, the model is represented as ZBW - 12/0.4 - □ - □ - □.
  • The first part "ZBW" indicates the prefabricated substation.
  • "12/0.4" represents the rated voltage levels, with 12kV for the high - voltage side and 0.4kV for the low - voltage side.
  • The subsequent boxes respectively denote the high - voltage measurement of rated voltage (KV), low - voltage measurement of rated voltage (KV), and rated capacity of the transformer (KVA).

 

 

 

Use Environment

 

The pad-mounted transformer must operate under specific environmental conditions to ensure stable performance and safe operation, with requirements integrated from both data sources as follows:

1. Cooling Condition
Adopts air self-cooling mode, relying on natural air circulation to dissipate heat generated during transformer operation, which is suitable for its structural design and common application scenarios.

 

2. Wind speed:
Equivalent to 34m/s (not more than 700 Pa);

 

3. Temperature Requirement
The outdoor ambient temperature shall not be higher than 40℃ and not lower than -45℃.
The monthly average temperature shall not exceed 30℃, and the annual average temperature shall not exceed 20℃. This limits the long-term temperature load on the transformer to avoid performance degradation caused by extreme temperature accumulation.

 

4. Altitude Requirement
The installation altitude shall not exceed 1000m.

 

5. Humidity Requirement
At a temperature of 25℃, the maximum relative humidity of the air shall not exceed 95%, and the daily average relative humidity shall not exceed 90%.

 

6. Vibration and Acceleration Requirement
The horizontal acceleration of the installation site shall not exceed 0.3g, and the vertical acceleration shall not exceed 0.15g).

 

7. Installation Platform Requirement
The installation site shall be clean, free from explosive or corrosive gases, conductive dust, strong vibration, and impact. The slope shall not exceed 3°, and the transformer must be placed on a flat, solid cement platform to ensure stability.

 

8. For product orders beyond the conditions specified above, please negotiate with our company.
 

 

 

Product Advantages

 

  • Compact structure, small size, easy installation.
  • Applicable to ring network and terminal power supply, ensuring personal safety.
  • Low loss, low noise, excellent performance, and anti-theft box structure.
  • Low temperature rise and strong overload capacity.

 

 

 

Product Structure Features

 

  • Transformer and Chambers: The pad-mounted transformer uses the 813 series oil-immersed transformer with a chip-type oil tank (no oil cushion, fully enclosed). High/low-pressure bushings, tap changers, oil level indicators, pressure release valves, oil release valves, etc., are mounted on the high-pressure chamber end plate for easy observation and operation. Its high/low-pressure chambers are separated by steel plates (relatively independent) and integrated into a complete box.
  • Components: It is equipped with plug - in fuses, pressure gauges, pressure relief valves, oil level gauges, oil thermometers, load switches, high - voltage cable joints, off - circuit tap changers, ground points, drain valves, and low - voltage switch cabinets, etc.
  • Load Switch: It is an oil - immersed, three - phase linkage switch with a spring operating mechanism. It can be operated with load, and its closing speed has nothing to do with the operating force. There are types such as two - station, four - station T type, and four - T position V type to choose from.
     

image003

 

 

 

Basic Construction and Technical Requirements

 

● Foundation Bearing Capacity and Protection
The foundation bearing capacity shall be not less than 100 kPa.

-If the foundation is located in highlands, external drainage systems shall be provided around it.

-The foundation shall be built with red brick cement mortar, and both inner and outer walls shall be plastered with 20mm-thick 1:2 cement mortar mixed with 3% waterproofing agent to enhance waterproofing.

-The concrete foundation surface shall be flat, and after installation of the prefabricated substation, the surrounding foundation shall be sealed with cement.

 

● Structure and Embedded Parts

-The bottom of the cable chamber shall be slightly inclined toward the water collection pipe to prevent water accumulation.

-A diamond-shaped expanded steel mesh (150×300 frame, 10×20 mesh size) shall be welded inside the louver frame, with reinforcement ribs embedded into the wall for enhanced strength.

-Grounding bars and cable fixing brackets shall be pre-embedded, and their shapes and positions shall be determined according to actual site conditions.

--The positions of incoming and outgoing cable holes shall also be determined as required on-site.

 

● Operation and Space

After installation of the prefabricated transformer substation, an operation clearance of not less than 1.5m shall be reserved in front of the switch to ensure safe operation and maintenance.

 

● Grounding System

-The grounding trunk shall be led out from the cable trench, and may be arranged around the ring main unit or extended to the grounding electrode from one side.

-The grounding grid shall be constructed with Φ12mm galvanized round steel or 30×4mm galvanized flat steel.

-The grounding resistance shall be ≤4Ω, in compliance with the requirements of the power authority.

 

● Construction Standards and Flexibility

-Foundation construction shall comply with JGJ/T16-92 "Code for Electrical Design of Civil Buildings".

-The dimensions shown in the drawings are recommended values. Cable wells can be arranged in three or four directions according to site conditions to meet different incoming line requirements.

 

 

 

Product Parameters

 

S/N

Name

Unit

Technical Parameter

1

Rated Voltage

KV

10/0.4

2

High-voltage Side Rated Voltage

KV

10

3

Low-voltage Side Rated Voltage

KV

0.4

4

Maximum operating voltage (High voltage side)

KV

12

5

Rated Frequency

Hz

50

6

Rated Capacity

KVA

150-1600

7

High-voltage Switch Heat Stable Capacity

KA

20/26

8

Low-voltage Main Circuit Breaker Rated Short-circuit Breaking Capacity

KA

35

9

Low-voltage Distribution Circuit Breaker Rated Short-circuit Breaking Capacity

KA

35

10

High-voltage Load Switch Transfer Current

A

>1500

11

1 min Power Frequency Withstand Voltage

KV

35

12

Lightning Impulse Voltage

KV

75

13

Cooling Mode

-

Oil immersed self-cooling

14

High-voltage Backup Fuse Breaking Current

KA

50

15

Breaking Current of Plug-in Fuse

KA

2.5

16

Ambient Temperature

℃

-35 ~ +40

17

Coil Allowable Temperature Rise

K

65

18

No-load Voltage Regulation

%

±5% or ±2 × 2.5%

19

Noise Level

dB

<50

20

Protection Grade of Box Shell

-

Not less than IP3X

 

Insulation Level

Rated voltage(KV)

10

0.4

Transformer

Switch to ground and phase to phase

Between disconnectors

Power frequency withstand voltage (KV)

35

42

48

2.5

Peak value of impulse withstand voltage(KV)

75

75

85

–

 

 

 

Transformer

 

Selected new S9 series transformer body, low loss, good overload capacity, strong short-circuit resistance, all fasteners are protected. The S11 series ring jointless core transformer with better performance can also be selected.

 

Capacity KVA

Voltage KV

Join group label

No-load current %

No load loss W

Impedance voltage %

Load loss

High tension

Low pressure

S9

S10

S11

S9

S10

S11

160

10±5% or 2×2.5%

0.4

Dyn11 Yno

1.4

1.4

0.2

400

320

255

4.0

2200

200

1.3

1.3

0.2

480

380

305

2600

250

1.2

1.2

0.2

560

450

360

3050

315

1.1

1.1

0.2

670

530

425

3650

400

1.0

1.0

0.15

800

650

505

4300

500

1.0

1.0

0.15

960

750

605

5100

630

0.9

0.9

0.15

1200

910

755

6200

800

0.8

0.8

0.15

1400

1080

980

7500

1000

0.7

0.7

-

1700

1260

-

4.5

10300

1250

0.6

0.6

-

1950

-

-

12000

 

Item

Name

Units

315A

630A

Rated voltage

KV

12

12

Maximum current

A

315

630

Rated frequency

Hz

50

50

Rated short-circuit closing current

kA

31.5

50

Rated short-time withstand current

kA

12.5

50

Rated short endurance time

S

2

2

Mechanical life

Second-rate

2000

2000

Lightning impulse test

Phase to phase

KV

75

75

Isolation fracture

85

85

1min power frequency withstand voltage

Phase to phase

KA

42

42

Isolation fracture

48

48

Rated peak withstand current

KV

31.5

50

 

Capacity

A

B

C

H

Weight KG

200kVA and below

1830

1420

820

1850

< 2800

250-400kVA

1830

1450

850

1980

3000-3300

500-630kVA

1830

1480

880

2070

3600-3950

800kVA

2200

1700

950

2170

4500

Note:The above is the standard size for reference.

 

Capacity

A

B

C

H

Weight KG

315kVA

2560

1600

600

1000

3050

400kVA

2560

1600

600

1000

3270

500kVA

2560

1600

600

1000

3400

630kVA

2560

1600

600

1000

3900

800kVA

2760

1600

800

1000

4200

1000kVA

2760

1950

800

1000

4800

1250kVA

2910

1950

800

1000

5400

1600kVA

2200

1700

950

2170

4500

Note:The above is the standard size for reference.

 

 

 

Drawings

 

 

image005

 

image007

 

image009

 

 

 

Detailed Views

 

image011001
image013
image015
image017001
image019
image021

 

 

 

Packing and Shipping

 

image025
image027
image029

 

 

 

Customer Factory Inspection

 

image031
image033
image035
image037
image039
image041

 

 

Hot Tags: 50 kva pad mount three-phase oil-immersed distribution transformer, China 50 kva pad mount three-phase oil-immersed distribution transformer manufacturers, suppliers, factory, 2500 KVA Pad Mount Three-Phase Oil-Immersed Distribution Transformer, 167 kva pad mount transformer, 5000 KVA Pad Mount Three-Phase Oil-Immersed Distribution Transformer, Single Phase Pad Mounted Transformer (URD Series), 1000 KVA Pad Mount Three-Phase Oil-Immersed Distribution Transformer, 25 kva pad mount transformer

Powering the World with Premium Transformer Solutions

As a leading Chinese transformer manufacturer with decades of expertise, CHBEB proudly serves clients across 17 countries and counting. Our global footprint expands continuously as we:

  • Deliver customized power solutions for more than 10 international projects
  • Support over 20 trusted distributors worldwide
  • Manufacture reliable low-voltage transformers with 60+ years of technical excellence

Let's energize your next power project with Chinese precision and global reliability.

Get in Touch with CHBEB

Leave a message for more information about our products series, and request a quote or expert advice.