Key Advantages
Featuring compact design and reliable performance, this 50 kVA pad-mounted transformer uses copper or aluminum windings and supports primary voltages of 10–35 kV at 50/60 Hz, providing efficient operation for residential or small-scale urban distribution networks.
Product Use
The pad - mounted transformer serves as an integrated prefabricated product that combines distribution network power supply unit cables, high - voltage control, protection, substation, and power distribution equipment. It is widely applied in urban and rural distribution networks. The transformer and high - low voltage equipment are closely connected into one unit. Three sides of the transformer are exposed to the air, ensuring good heat dissipation conditions. Moreover, the transformer can be separated from the high - low voltage equipment housing, facilitating maintenance. Power distribution switchgear is installed on the high and low voltage sides.
Model Description
- Taking the ZBW series as an example, the model is represented as ZBW - 12/0.4 - □ - □ - □.
- The first part "ZBW" indicates the prefabricated substation.
- "12/0.4" represents the rated voltage levels, with 12kV for the high - voltage side and 0.4kV for the low - voltage side.
- The subsequent boxes respectively denote the high - voltage measurement of rated voltage (KV), low - voltage measurement of rated voltage (KV), and rated capacity of the transformer (KVA).
Use Environment
The pad-mounted transformer must operate under specific environmental conditions to ensure stable performance and safe operation, with requirements integrated from both data sources as follows:
1. Cooling Condition
Adopts air self-cooling mode, relying on natural air circulation to dissipate heat generated during transformer operation, which is suitable for its structural design and common application scenarios.
2. Wind speed:
Equivalent to 34m/s (not more than 700 Pa);
3. Temperature Requirement
The outdoor ambient temperature shall not be higher than 40℃ and not lower than -45℃.
The monthly average temperature shall not exceed 30℃, and the annual average temperature shall not exceed 20℃. This limits the long-term temperature load on the transformer to avoid performance degradation caused by extreme temperature accumulation.
4. Altitude Requirement
The installation altitude shall not exceed 1000m.
5. Humidity Requirement
At a temperature of 25℃, the maximum relative humidity of the air shall not exceed 95%, and the daily average relative humidity shall not exceed 90%.
6. Vibration and Acceleration Requirement
The horizontal acceleration of the installation site shall not exceed 0.3g, and the vertical acceleration shall not exceed 0.15g).
7. Installation Platform Requirement
The installation site shall be clean, free from explosive or corrosive gases, conductive dust, strong vibration, and impact. The slope shall not exceed 3°, and the transformer must be placed on a flat, solid cement platform to ensure stability.
8. For product orders beyond the conditions specified above, please negotiate with our company.
Product Advantages
- Compact structure, small size, easy installation.
- Applicable to ring network and terminal power supply, ensuring personal safety.
- Low loss, low noise, excellent performance, and anti-theft box structure.
- Low temperature rise and strong overload capacity.
Product Structure Features
- Transformer and Chambers: The pad-mounted transformer uses the 813 series oil-immersed transformer with a chip-type oil tank (no oil cushion, fully enclosed). High/low-pressure bushings, tap changers, oil level indicators, pressure release valves, oil release valves, etc., are mounted on the high-pressure chamber end plate for easy observation and operation. Its high/low-pressure chambers are separated by steel plates (relatively independent) and integrated into a complete box.
- Components: It is equipped with plug - in fuses, pressure gauges, pressure relief valves, oil level gauges, oil thermometers, load switches, high - voltage cable joints, off - circuit tap changers, ground points, drain valves, and low - voltage switch cabinets, etc.
- Load Switch: It is an oil - immersed, three - phase linkage switch with a spring operating mechanism. It can be operated with load, and its closing speed has nothing to do with the operating force. There are types such as two - station, four - station T type, and four - T position V type to choose from.

Basic Construction and Technical Requirements
● Foundation Bearing Capacity and Protection
The foundation bearing capacity shall be not less than 100 kPa.
-If the foundation is located in highlands, external drainage systems shall be provided around it.
-The foundation shall be built with red brick cement mortar, and both inner and outer walls shall be plastered with 20mm-thick 1:2 cement mortar mixed with 3% waterproofing agent to enhance waterproofing.
-The concrete foundation surface shall be flat, and after installation of the prefabricated substation, the surrounding foundation shall be sealed with cement.
● Structure and Embedded Parts
-The bottom of the cable chamber shall be slightly inclined toward the water collection pipe to prevent water accumulation.
-A diamond-shaped expanded steel mesh (150×300 frame, 10×20 mesh size) shall be welded inside the louver frame, with reinforcement ribs embedded into the wall for enhanced strength.
-Grounding bars and cable fixing brackets shall be pre-embedded, and their shapes and positions shall be determined according to actual site conditions.
--The positions of incoming and outgoing cable holes shall also be determined as required on-site.
● Operation and Space
After installation of the prefabricated transformer substation, an operation clearance of not less than 1.5m shall be reserved in front of the switch to ensure safe operation and maintenance.
● Grounding System
-The grounding trunk shall be led out from the cable trench, and may be arranged around the ring main unit or extended to the grounding electrode from one side.
-The grounding grid shall be constructed with Φ12mm galvanized round steel or 30×4mm galvanized flat steel.
-The grounding resistance shall be ≤4Ω, in compliance with the requirements of the power authority.
● Construction Standards and Flexibility
-Foundation construction shall comply with JGJ/T16-92 "Code for Electrical Design of Civil Buildings".
-The dimensions shown in the drawings are recommended values. Cable wells can be arranged in three or four directions according to site conditions to meet different incoming line requirements.
Product Parameters
|
S/N |
Name |
Unit |
Technical Parameter |
|
1 |
Rated Voltage |
KV |
10/0.4 |
|
2 |
High-voltage Side Rated Voltage |
KV |
10 |
|
3 |
Low-voltage Side Rated Voltage |
KV |
0.4 |
|
4 |
Maximum operating voltage (High voltage side) |
KV |
12 |
|
5 |
Rated Frequency |
Hz |
50 |
|
6 |
Rated Capacity |
KVA |
150-1600 |
|
7 |
High-voltage Switch Heat Stable Capacity |
KA |
20/26 |
|
8 |
Low-voltage Main Circuit Breaker Rated Short-circuit Breaking Capacity |
KA |
35 |
|
9 |
Low-voltage Distribution Circuit Breaker Rated Short-circuit Breaking Capacity |
KA |
35 |
|
10 |
High-voltage Load Switch Transfer Current |
A |
>1500 |
|
11 |
1 min Power Frequency Withstand Voltage |
KV |
35 |
|
12 |
Lightning Impulse Voltage |
KV |
75 |
|
13 |
Cooling Mode |
- |
Oil immersed self-cooling |
|
14 |
High-voltage Backup Fuse Breaking Current |
KA |
50 |
|
15 |
Breaking Current of Plug-in Fuse |
KA |
2.5 |
|
16 |
Ambient Temperature |
℃ |
-35 ~ +40 |
|
17 |
Coil Allowable Temperature Rise |
K |
65 |
|
18 |
No-load Voltage Regulation |
% |
±5% or ±2 × 2.5% |
|
19 |
Noise Level |
dB |
<50 |
|
20 |
Protection Grade of Box Shell |
- |
Not less than IP3X |
Insulation Level
|
Rated voltage(KV) |
10 |
0.4 |
||
|
Transformer |
Switch to ground and phase to phase |
Between disconnectors |
||
|
Power frequency withstand voltage (KV) |
35 |
42 |
48 |
2.5 |
|
Peak value of impulse withstand voltage(KV) |
75 |
75 |
85 |
– |
Transformer
Selected new S9 series transformer body, low loss, good overload capacity, strong short-circuit resistance, all fasteners are protected. The S11 series ring jointless core transformer with better performance can also be selected.
|
Capacity KVA |
Voltage KV |
Join group label |
No-load current % |
No load loss W |
Impedance voltage % |
Load loss |
|||||
|
High tension |
Low pressure |
S9 |
S10 |
S11 |
S9 |
S10 |
S11 |
||||
|
160 |
10±5% or 2×2.5% |
0.4 |
Dyn11 Yno |
1.4 |
1.4 |
0.2 |
400 |
320 |
255 |
4.0 |
2200 |
|
200 |
1.3 |
1.3 |
0.2 |
480 |
380 |
305 |
2600 |
||||
|
250 |
1.2 |
1.2 |
0.2 |
560 |
450 |
360 |
3050 |
||||
|
315 |
1.1 |
1.1 |
0.2 |
670 |
530 |
425 |
3650 |
||||
|
400 |
1.0 |
1.0 |
0.15 |
800 |
650 |
505 |
4300 |
||||
|
500 |
1.0 |
1.0 |
0.15 |
960 |
750 |
605 |
5100 |
||||
|
630 |
0.9 |
0.9 |
0.15 |
1200 |
910 |
755 |
6200 |
||||
|
800 |
0.8 |
0.8 |
0.15 |
1400 |
1080 |
980 |
7500 |
||||
|
1000 |
0.7 |
0.7 |
- |
1700 |
1260 |
- |
4.5 |
10300 |
|||
|
1250 |
0.6 |
0.6 |
- |
1950 |
- |
- |
12000 |
||||
|
Item Name |
Units |
315A |
630A |
|
|
Rated voltage |
KV |
12 |
12 |
|
|
Maximum current |
A |
315 |
630 |
|
|
Rated frequency |
Hz |
50 |
50 |
|
|
Rated short-circuit closing current |
kA |
31.5 |
50 |
|
|
Rated short-time withstand current |
kA |
12.5 |
50 |
|
|
Rated short endurance time |
S |
2 |
2 |
|
|
Mechanical life |
Second-rate |
2000 |
2000 |
|
|
Lightning impulse test |
Phase to phase |
KV |
75 |
75 |
|
Isolation fracture |
85 |
85 |
||
|
1min power frequency withstand voltage |
Phase to phase |
KA |
42 |
42 |
|
Isolation fracture |
48 |
48 |
||
|
Rated peak withstand current |
KV |
31.5 |
50 |
|
|
Capacity |
A |
B |
C |
H |
Weight KG |
|
200kVA and below |
1830 |
1420 |
820 |
1850 |
< 2800 |
|
250-400kVA |
1830 |
1450 |
850 |
1980 |
3000-3300 |
|
500-630kVA |
1830 |
1480 |
880 |
2070 |
3600-3950 |
|
800kVA |
2200 |
1700 |
950 |
2170 |
4500 |
Note:The above is the standard size for reference.
|
Capacity |
A |
B |
C |
H |
Weight KG |
|
315kVA |
2560 |
1600 |
600 |
1000 |
3050 |
|
400kVA |
2560 |
1600 |
600 |
1000 |
3270 |
|
500kVA |
2560 |
1600 |
600 |
1000 |
3400 |
|
630kVA |
2560 |
1600 |
600 |
1000 |
3900 |
|
800kVA |
2760 |
1600 |
800 |
1000 |
4200 |
|
1000kVA |
2760 |
1950 |
800 |
1000 |
4800 |
|
1250kVA |
2910 |
1950 |
800 |
1000 |
5400 |
|
1600kVA |
2200 |
1700 |
950 |
2170 |
4500 |
Note:The above is the standard size for reference.
Drawings



Detailed Views






Packing and Shipping



Customer Factory Inspection






Hot Tags: 50 kva pad mount three-phase oil-immersed distribution transformer, China 50 kva pad mount three-phase oil-immersed distribution transformer manufacturers, suppliers, factory, 2500 KVA Pad Mount Three-Phase Oil-Immersed Distribution Transformer, 167 kva pad mount transformer, 5000 KVA Pad Mount Three-Phase Oil-Immersed Distribution Transformer, Single Phase Pad Mounted Transformer (URD Series), 1000 KVA Pad Mount Three-Phase Oil-Immersed Distribution Transformer, 25 kva pad mount transformer