Product Overview
The 16000 kVA oil-filled transformeris engineered for high-capacity power conversion, combining oil-immersed insulation with an efficient cooling structure and a robust core-and-winding assembly. Its integrated design supports stable electrical performance under demanding operating conditions, while the oil-filled construction helps manage heat and insulation requirements for continuous-duty operation.
16000 kVA transformer undergoing high voltage dielectric testing
in the factory laboratory.
Technical Specifications
|
Parameter |
Standard Specification |
|
Product Name |
16000 kVA Oil-Filled Transformer |
|
Transformer Type |
Three-Phase Oil-Filled Power Transformer with OLTC |
|
Rated Capacity |
16000 kVA |
|
Number of Phases |
Three-phase |
|
Rated Frequency |
50 Hz |
|
Rated Primary Voltage |
33 kV |
|
Rated Secondary Voltage |
11 kV |
|
HV Tapping Range |
±8 × 1.25%, 17 positions |
|
Tap-Changing Method |
On-load tap changing |
|
Vector Group |
YNd11 |
|
Short-Circuit Impedance |
10.0% |
|
No-Load Current |
≤0.5% |
|
Cooling Method |
ONAN/ONAF |
|
Insulating Liquid |
PCB-free mineral insulating oil |
|
Winding Material |
Copper |
|
Core Material |
Cold-rolled grain-oriented silicon steel |
|
Winding Temperature Rise |
65 K |
|
Tank Construction |
Conservator-type tank with detachable radiators, cooling fans, and control cabinet |
|
Protection and Monitoring |
Main-tank and OLTC gas protection, differential-protection interface, pressure relief, liquid-level, oil and winding temperature monitoring, alarm and trip contacts |
|
Installation |
Outdoor installation, continuous duty |
|
Service Conditions |
Maximum ambient temperature: 40°C; maximum altitude: 1,000 m |
|
Certification Standards |
Available according to IEC, IEEE/ANSI, DOE (where applicable), CSA, CE/EN, UKCA, GOST/EAC, SASO/SABER, SONCAP, ISO, and other required certification schemes |
Advantages of CHBEB 16000 kVA Oil-Filled Transformer
CHBEB 16000 kVA oil-filled transformers are engineered for high-capacity transmission and distribution duty, combining vacuum OLTC technology, advanced thermal monitoring, and optimized impedance design to support reliable grid operation.
Maintenance-Free Voltage Regulation
The OLTC system uses vacuum interrupter technology to quench arcs inside sealed vacuum bottles instead of insulating oil. This keeps the oil free from carbon sludge and preserves dielectric strength in the tap compartment, extending the maintenance interval from 50,000 operations to over 300,000 operations and significantly reducing lifecycle costs for utility operators.
Precision Thermal Monitoring
Fiber optic temperature sensors can be embedded directly into winding hot spots during manufacturing, providing real-time, lag-free data on winding insulation temperature. This enables precise dynamic loading, allowing operators to safely push the transformer beyond nameplate rating during emergency grid events without compromising insulation life.
Impedance & Short Circuit Engineering
The electrical geometry is optimized for high reactance, with a standard impedance voltage (Uk) of 10.0%. This high impedance value limits secondary short-circuit current to below 25 kA/31.5 kA, protecting downstream 11 kV switchgear from explosive mechanical forces and supporting proper grid coordination.


Typical Application Context
- Zonal Substations
- Hyperscale Data Center Campuses
- Large-Scale Metallurgical Plants
- Chemical Electrolysis Facilities
- Urban Power Distribution Networks
- Industrial Parks and Manufacturing Hubs
- High-Voltage Transmission Substations
- Large-Scale Infrastructure Projects
16000 kVA oil immersed transformer powering a hyperscale
data center campus.
Customize 16000 Kva Oil-filled Transformer for Your Distribution Project
CHBEB provides configurable electrical, structural, protection, and documentation options to match project-specific distribution requirements.
- Electrical Ratings - Customize rated capacity, primary and secondary voltage, frequency, impedance, and tap configuration according to project requirements.
- Winding & Core Materials - Select copper or aluminum windings and suitable core materials according to required electrical performance and specifications.
- Protection & Enclosure - Configure fuse protection, bushing arrangements, cabinet access, and weather-resistant enclosure requirements.
- Mounting & Dimensions - Adapt pad-mounted dimensions, cable entry arrangements, compartment configuration, and other structural details to suit installation conditions.
- Testing & Documentation - Provide project-specific testing, technical drawings, nameplate information, and inspection documents according to customer or utility requirements.
- Branding & Packaging - Customize nameplates, labels, packaging marks, and shipping packaging according to branding and delivery requirements.

Highlights of CHBEB Oil-Filled Transformer Manufacturing Process
CHBEB oil-filled transformers are built through a rigorous manufacturing and quality assurance process designed to ensure exceptional reliability, low loss, and long-term operational safety in power distribution networks.
- Raw Material Selection - We source raw materials exclusively from trusted suppliers, utilizing high-permeability silicon steel sheets from Baowu Steel and top domestic producers, alongside premium insulation materials like DuPont Nomex® paper that undergo strict magnetic loss and thermal class testing to meet IEC 60641 standards.
- Core Lamination & Winding - Our core lamination utilizes precision CNC cutting and automated stacking followed by stress-relieving annealing to minimize no-load loss and noise, while automated coil winding machines guarantee precise turns, uniform tension, and strict adherence to IEEE C57.12.00 standards.
- Insulation Control - For oil-immersed transformers, we apply high-grade electrical pressboard, crepe paper, and refined transformer oil to establish a robust insulation system that delivers superior heat dissipation and electrical stability.
- Transformer Assembly - Windings and high-quality silicon steel laminations are carefully assembled and installed into in-house manufactured robust corrugated steel oil tanks, followed by advanced vacuum drying and precise oil filling to completely eliminate moisture and air.
- Testing & Quality Assurance - Every transformer undergoes a comprehensive suite of factory testing-including winding resistance, voltage ratio, no-load and load loss measurements, as well as rigorous dielectric and partial discharge tests-to verify full electrical reliability and compliance with international standards before delivery.
Oil-Filled Transformer Assembly
Why Choose CHBEB as Your Transformer Manufacturer
CHBEB brings extensive experience and established manufacturing resources to transformer projects worldwide.
69+ Years of Manufacturing Experience
Founded in 1956, CHBEB has more than 69 years of experience in power and specialty transformer manufacturing, serving power transmission and distribution applications in different markets.
Three Self-Owned Manufacturing Bases
CHBEB operates three self-owned manufacturing bases: No. 211, Wei 16 Road, Yueqing, Zhejiang; Xiangyang Industrial Zone, Yueqing, Zhejiang; and No. 7, Xiangfeng Road, Jiangning District, Nanjing, Jiangsu. The facilities span over 100 acres with an annual production value of RMB 3 billion.
Engineering & Technical Support
CHBEB provides technical drawings and engineering support for transformer projects, allowing buyers to confirm electrical specifications, product dimensions, and installation requirements before production.
Green Manufacturing
CHBEB uses automated precision equipment to reduce material waste and energy consumption while integrating clean energy into its manufacturing facilities. Our supply chain also emphasizes responsibly sourced transformer materials.
Comprehensive Service Support from CHBEB for Your Transformer Projects
CHBEB provides practical support from technical evaluation and project coordination to delivery and after-sales service.
Technical Support & Free Design Drawings
CHBEB provides technical assistance and drawings to help customers confirm transformer specifications and equipment requirements before production.
Support includes:
• Free technical drawings for project evaluation
• Transformer specification and selection support
• Electrical and installation requirement consultation
• Product dimension and interface confirmation
• Responsive technical communication
Fast Production & Logistics Support
CHBEB coordinates production and shipment according to project schedules, product requirements, and delivery conditions.
Support includes:
• Standard lead time of 3–6 weeks
• Expedited delivery available within 1 week
• Production scheduling based on project requirements
• Export packaging for transformer transportation
• Shipping and logistics coordination
After-Sales & Lifecycle Support
CHBEB provides technical assistance and warranty coverage to support reliable transformer operation throughout its service life.
After-sales support includes:
• 3-year warranty for complete transformers
• 2-year warranty for spare parts
• Free lifecycle maintenance guidance
• Installation and commissioning guidance
• Technical troubleshooting and operation support
FAQ
Q: How should the 16000 kVA oil-filled transformer be protected against lightning and switching surges?
A: Surge protection should be selected according to the system voltage, insulation coordination requirements, and installation conditions. Suitable surge arresters and grounding arrangements help protect transformer insulation against transient overvoltages.
Q: Can the 16000 kVA oil-filled transformer be configured for different grid connection requirements?
A: Yes. Key electrical parameters, including primary and secondary voltages, vector group, short-circuit impedance, and tap range, can be specified to match the project's grid connection and load requirements.
Q: What information should buyers provide when requesting a quotation for a 16000 kVA oil-filled transformer?
A: Provide the rated capacity, primary and secondary voltages, frequency, vector group, impedance, cooling requirements, installation environment, and applicable standards. A single-line diagram and project-specific protection requirements can further improve quotation accuracy.
Q: Can the transformer's protection and monitoring interfaces be integrated with a substation control system?
A: Yes, the required monitoring signals and protection interfaces can be specified during engineering. Confirm the required alarm and trip contacts, temperature and oil-level signals, gas protection, and differential protection interfaces before production.
Q: What site preparations are required before installing a 16000 kVA oil-filled transformer?
A: Prepare a foundation suitable for the transformer's operating weight, adequate clearance for radiator and cooling-fan maintenance, appropriate grounding, and access for transport and lifting equipment. Oil containment, fire protection, and electrical clearances should also comply with local regulations and project specifications.
Hot Tags: 16000 kva oil-filled transformer, China 16000 kva oil-filled transformer manufacturers, suppliers, factory, 100 Kva Oil-filled Transformer, 3750 Kva Oil-filled Transformer, 6000 Kva Oil-filled Transformer, 500 Kva Oil-filled Transformer, 4000 Kva Oil-filled Transformer, 1250 Kva Oil-filled Transformer