Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Description

 

summary

(H) RW□-□ (F) series outdoor high voltage AC drop fuse (hereinafter referred to as "fuse") is applicable to the outdoor overhead distribution systems with a rated frequency of 50Hz and rated voltage of 10kV(12/15/35/40.5). It is used as a protective element of circuit or electrical equipment in case of overload or short circuit fault of a power system. When traveling normally, the fuse is connected in series in the power line, the fuse is in a tensioned state, and the movable joint is locked. When the line fails, the fault current causes the fuse to blow, the movable joint is released, the fuse tube is quickly dropped, and the circuit is cut off, which plays a role in safety protection for the maintenance of the line and equipment. The load type fuse is added with elastic contact and arc extinguishing cover on the basis of the ordinary type, which is used to open and close the load current in the power system.

 

The fuse shall comply with technical standards such as GB / T 15166.3 - 2008 high voltage AC fuses - Part 3: injection fuses, DL / T 640 - 1997 outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions.

Model Description:

 

 

Working Environment:

◆Ambient temperature: -40C +40C;

◆Relative humidity: the daily average is not more than 95%, and the monthly average is not more than 90%;

◆The altitude does not exceed 3000m;

◆Outdoor wind speed not exceeding 34 meters/second;

◆Installation site: no fire, explosion hazard, chemical corrosive gas and well-ventilated place.

Note: When the above normal use conditions are exceeded, the user can negotiate with the company.

 

 

Technical parameters

 Note: Our company can supply products according to user requirements.

Model


Rated

Voltage
kV


Rated

Current
A

 

Rated

maximum

breaking current
kA

 

1min power

frequency

dry

withstand

voltage
(valid value)
kV

 

1min power

frequency

wet

withstand

voltage
(valid value)
kV

Rated

lightning

impulse

withstand

voltage
(peak)
kV

 Opening

and

closing

load current
A

XS-12/100(200)

12

100

(200)

6.3

(12.5)

42

30

75

/

XS-15/100(200

15

PD-12/100(200)

12

100

(200)

6.3

(12.5)

42

30

75

/

PD-15/100(200)

15

(H)RW3-10/100(200)

10

100

(200)

6.3

(12.5)

42

30

75

/

(H)RW3-12/100(200)

12

(H)RW4-10/100(200)

10

100

(200)

6.3

(12.5)

42

30

75

/

(H)RW4-12/100(200)

12

(H)RW7-10/100(200)

10

100

(200)

6.3

(12.5)

42

30

75

/

(H)RW7-12/100(200)

12

(H)RW10-10/100(200)

10

100

(200)

6.3

(12.5)

42

30

75

/

(H)RW10-12/100(200)

12

(H)RW10-10F/100(200)

10

100

(200)

6.3

(12.5)

42

30

75

10
(200)

(H)RW10-12F/100(200)

12

(H)RW11-10/100(200)

10

100

(200)

6.3

(12.5)

42

30

75

!

(H)RW11-12/100(200)

12

(H)RW11-10F/100(200)

10

100

(200)

6.3

(12.5)

42

30

75

10
(200)

(H)RW11-12F/100(200)

12

(H)RW12-10/100(200)

10

100

(200)

6.3

(12.5)

45

30
(38)

105

/

(H)RW12-12/100(200)

12

(H)RW12-15/100(200)

15

(H)PRWG1-10F/100(200)

10

100

(200)

6.3

(12.5)

42

30

75

10
(200)

(H)PRWG1-12F/100(200)

12

(H)RW33-12/100(200)

12

100

(200)

6.3

(12.5)

42

30

75

/

(H)RW33-15/100(200)

15

(H)RW5-35/100(200)

35

100

(200)

6.3

(12.5)

95

86

185

/

40.5

(H)RW10-35/100(200)

35

100

(200)

6.3

(12.5)

95

86

185

/

40.5

(H)PRWG2-35/100(200)

35

100

(200)

6.3

(12.5)

95

86

185

/

40.5